Kang Sung-yong, chief director of Irium Eye Clinic, co-authored a research paper with overseas researchers on centering in vision correction surgery, and it was published last October in the international ophthalmology journal Translational Vision Science & Technology.
The paper is titled ‘Geometric Principles of a Novel Asymmetric Transition Zone Centering Strategy for Refractive Surgery.’ Based on related research presented at the ARVO 2026 international conference last May, the study analyzed the geometric principles and theoretical potential of a new design strategy to compensate for centering errors that may occur during surgery.
Corneal lenticule extraction-based vision correction surgery, KLEx, discussed in this study is a collective term for surgical procedures that include SMILE LASIK and SmartSight NOVA. The procedure corrects myopia and astigmatism by creating a thin, lens-shaped piece of tissue inside the cornea with a laser and then separating and removing it. This study proposed a new approach to improving centering accuracy in these procedures.
In vision correction surgery, it is important not only to correct myopia and astigmatism accurately but also to precisely establish the center position where the laser is applied. In particular, if the gaze shifts slightly or the eye rotates while the eye is being fixated for surgery, a difference may arise between the planned correction center and the actual surgical center. Such decentration is associated with an increase in higher-order aberrations, HOA, and may affect visual quality through nighttime halos, glare, and reduced contrast sensitivity.
The asymmetric transition zone, aTZ, strategy proposed in this study matches the central optical zone, where vision correction is performed, to the target position and uses an asymmetrically designed transition zone, the surrounding connecting area, to compensate for positional errors.
In conventional symmetric transition-zone designs, if positional errors occurring during surgery are not corrected, even the central optical zone may deviate from its planned position. By contrast, aTZ is designed to compensate for centering errors by maintaining the alignment of the central optical zone while adjusting the shape of the surrounding transition zone.
When the researchers theoretically compared and analyzed aTZ with conventional methods, they found that aTZ could compensate for centering errors while maintaining the same central thickness as the conventional symmetric design. The total volume of corneal tissue used decreased slightly, and the study also presented the theoretical potential to preserve optical quality by redistributing higher-order aberrations caused by decentration to the surrounding transition zone.
In the actual surgical case introduced in the paper, a positional error of approximately 0.3 mm was detected during the process of fixing the eye to the laser equipment, compared with the planned reference position. Accordingly, the optical zone was shifted by 0.2 mm, the maximum permitted movement under the aTZ design. Corneal topography and thickness analysis 16 days after surgery showed a centering pattern consistent with the predicted design. Analysis of higher-order aberrations also showed that the preoperative characteristics were maintained, with no clinically meaningful new higher-order aberrations induced.
The study is particularly significant because it extended the concept of customized transition-zone design, which was developed through conventional excimer laser vision correction surgery, to lenticule-based vision correction surgery. The aTZ strategy examined in the study is the design method applied to CenTrax, the centering technology used in SmartSight NOVA.
Kang Sung-yong, chief director of Irium Eye Clinic, said, “In lenticule-based vision correction surgery such as SMILE, it is important not only to correct myopia and astigmatism accurately but also to precisely align the vision correction center. This study is significant because it proposed a new design strategy that maintains the alignment of the central optical zone while compensating for minute positional errors that may occur during surgery.”
He added, “This study extends the customized design concept developed through conventional excimer laser surgery to corneal lenticule-based vision correction surgery. We expect it to contribute to the development of precision vision correction technology that considers both the preservation of postoperative visual quality and the amount of corneal tissue used.”
The paper is titled ‘Geometric Principles of a Novel Asymmetric Transition Zone Centering Strategy for Refractive Surgery.’ Based on related research presented at the ARVO 2026 international conference last May, the study analyzed the geometric principles and theoretical potential of a new design strategy to compensate for centering errors that may occur during surgery.
Corneal lenticule extraction-based vision correction surgery, KLEx, discussed in this study is a collective term for surgical procedures that include SMILE LASIK and SmartSight NOVA. The procedure corrects myopia and astigmatism by creating a thin, lens-shaped piece of tissue inside the cornea with a laser and then separating and removing it. This study proposed a new approach to improving centering accuracy in these procedures.
In vision correction surgery, it is important not only to correct myopia and astigmatism accurately but also to precisely establish the center position where the laser is applied. In particular, if the gaze shifts slightly or the eye rotates while the eye is being fixated for surgery, a difference may arise between the planned correction center and the actual surgical center. Such decentration is associated with an increase in higher-order aberrations, HOA, and may affect visual quality through nighttime halos, glare, and reduced contrast sensitivity.
The asymmetric transition zone, aTZ, strategy proposed in this study matches the central optical zone, where vision correction is performed, to the target position and uses an asymmetrically designed transition zone, the surrounding connecting area, to compensate for positional errors.
In conventional symmetric transition-zone designs, if positional errors occurring during surgery are not corrected, even the central optical zone may deviate from its planned position. By contrast, aTZ is designed to compensate for centering errors by maintaining the alignment of the central optical zone while adjusting the shape of the surrounding transition zone.
When the researchers theoretically compared and analyzed aTZ with conventional methods, they found that aTZ could compensate for centering errors while maintaining the same central thickness as the conventional symmetric design. The total volume of corneal tissue used decreased slightly, and the study also presented the theoretical potential to preserve optical quality by redistributing higher-order aberrations caused by decentration to the surrounding transition zone.
In the actual surgical case introduced in the paper, a positional error of approximately 0.3 mm was detected during the process of fixing the eye to the laser equipment, compared with the planned reference position. Accordingly, the optical zone was shifted by 0.2 mm, the maximum permitted movement under the aTZ design. Corneal topography and thickness analysis 16 days after surgery showed a centering pattern consistent with the predicted design. Analysis of higher-order aberrations also showed that the preoperative characteristics were maintained, with no clinically meaningful new higher-order aberrations induced.
The study is particularly significant because it extended the concept of customized transition-zone design, which was developed through conventional excimer laser vision correction surgery, to lenticule-based vision correction surgery. The aTZ strategy examined in the study is the design method applied to CenTrax, the centering technology used in SmartSight NOVA.
Kang Sung-yong, chief director of Irium Eye Clinic, said, “In lenticule-based vision correction surgery such as SMILE, it is important not only to correct myopia and astigmatism accurately but also to precisely align the vision correction center. This study is significant because it proposed a new design strategy that maintains the alignment of the central optical zone while compensating for minute positional errors that may occur during surgery.”
He added, “This study extends the customized design concept developed through conventional excimer laser surgery to corneal lenticule-based vision correction surgery. We expect it to contribute to the development of precision vision correction technology that considers both the preservation of postoperative visual quality and the amount of corneal tissue used.”